MODEL
|
FIELDS
|
SERIAL NUMBER SUFFIX
|
PRE-AMP BOARD
|
OUTPUT
|
ION CHAMBER THICKNESS
|
APPLICATION
|
|
ICX143
|
A = 2
B = 1
C = 3
|
AF & up
AC-AE
AA-AB
|
61154N
61135A
61116A
|
POS.
|
0.28-Inch (7.1mm)
|
GENDEX / PICKER TABLE BUCKY
(L.H. LOAD)
-AID COMPATIBLE-
|
|
ICX167
|
A = 2
B = 1
C = 3
|
AA & up
|
60917J
|
POS.
or
NEG.
|
0.4-Inch (10.2mm)
|
PICKER 4-FIELD
14x14 SPOT
-AID/PICKER
COMPATIBLE-
|
|
ICX183
|
A = 2
B = 1
C = 3
|
AC & up
AA-AB
|
61154G
60917I
|
POS.
|
0.4-Inch (10.2mm)
|
14 X 36 CASSETTE
- PICKER COMPATIBLE
-
|
|
ICX195
|
A = 2
B = 1
(B+C) = 3
|
AA & up
|
61112A
|
NEG.
|
0.28-Inch (7.1mm)
|
PICKER SPOT FILMER
- PICKER COMPATIBLE
-
|
|
ICX197
|
A = 2
B = 1
C = 3
|
AN & up
AM
AK-AL
AA-AJ
|
61154N
61170N
61135A
60917F
|
NEG.
|
0.28-Inch (7.1mm)
|
PICKER TABLE BUCKY
OBSOLETE REPLACED BY
ICX143
- PICKER COMPATIBLE
-
|
|
ICX197
GENDEX
|
A = 2
B = 1
C = 3
|
AA & up
|
61116A
|
NEG.
|
0.28-Inch (7.1mm)
|
GENDEX-PICKER
TABLE BUCKY
OBSOLETE REPLACED BY
ICX143
- PICKER COMPATIBLE
-
|
|
ICX226
|
A = 1
B = 2
C = 3
|
AA & up
Other Docs
|
61170S
705208 |
POS.
|
0.12-Inch (3.3mm)
|
FUJI VELOCITY
17 X17 CHEST STAND
- PICKER COMPATIBLE -
|
|
ICX801
|
SPOT
2-Inch (51mm) SQ.
|
AB & up
AA
|
61125B
60940F
|
NEG.
|
0.4-Inch (10.2mm)
|
EXIT-TYPE
PEDIATRIC SPOT FILM DEVICE
- PICKER COMPATIBLE
-
|
|
ICX811L
|
A = 2
B = 1
C = 3
|
AB & up
AA
|
61154L
61135L
|
NEG.
|
0.4-Inch (10.2mm)
|
POERSCH METALS
CHEST STAND
L.H. LOAD
- PICKER COMPATIBLE
-
|
|
ICX818
|
A = 2
B = 1
C = 3
|
AG & up
AF
AA-AE
Other Docs
|
61135A
61116A
60917F
705100
|
NEG.
|
0.28-Inch (7.1mm)
|
FUJI FCR9501, FCR9501HQ
- PICKER COMPATIBLE
-
|
|
ICX821
|
A = 2
B = 1
C = 3
|
AD & up
AC
AA-AB
Other Docs
|
61154C
61135A
61116A
705140
|
NEG.
|
0.34-Inch (8.4mm)
|
FUJI FCR 9502/HQ TABLE
- PICKER COMPATIBLE
-
|
|
ICX822
|
A = 2
B = 1
C = 3
|
AF & up
AA-AE
Other Docs
|
61170S
61135A
705207
705147
|
NEG.
|
0.28-Inch (7.1mm)
|
CANON DIGITAL RADIOGRAPHIC SYSTEM
- PICKER COMPATIBLE
-
|
|
ICX823
|
A = 2
B = 1
C = 3
|
AE & up
AD
AC
AA-AB
Other Docs
|
61154C
61135C
61116C
61116A
705141
|
NEG.
|
0.28-Inch (7.1mm)
|
FUJI FCR 9501-ES
DIGITAL RADIOGRAPHIC CHEST STAND
- PICKER COMPATIBLE
-
|
|
ICX824
|
A = 2
B = 1
C = 3
|
AF & up
AD-AE
AA-AC
Other Docs
|
61154C
61135C
61116C
705150
|
NEG.
|
0.22-Inch (5.7mm)
|
FUJI FCR 5501
17X17 CHEST DIGITAL RADIOGRAPHIC SYSTEM
- PICKER COMPATIBLE
-
|
|
ICX825L
|
A = 2
B = 1
C = 3
|
AB & up
AA
Other Docs
|
61154C
61135C
705177
|
SUMMED DC LEVEL
|
0.22-Inch (5.7mm)
|
FUJI FCR 5502
17X17 TABLE DIGITAL RADIOGRAPHIC SYSTEM
FOR HEAD-END LEFT
with REMOTE PRE-AMP
- PICKER COMPATIBLE
-
|
|
ICX826
|
A = 2
B = 1
C = 3
|
AB & up
AA
Other Docs
|
61170S
61170C
705208
|
NEG.
|
0.12-Inch (3.3mm)
|
FUJI VELOCITY
17 X17 CHEST STAND
- PICKER COMPATIBLE
-
|
|
ICX846
|
A = 2
B = 1
C = 3
|
AC & up
AA-AB
|
61154N
61135A
|
NEG.
|
0.28-Inch (7.1mm)
|
DIRECT RADIOGRAPHY CORP.
DIGITAL CHEST STAND
- PICKER COMPATIBLE
-
|
|
ICX848
|
A = 2
B = 1
C = 3
|
AA & up
|
61116A
|
NEG.
|
0.4-Inch (10.2mm)
|
BIODEX TRAUMA TABLE
- PICKER COMPATIBLE
-
|
|
ICX853
|
A = 2
B = 1
C = 3
|
AC & up
AA-AB
|
61154J
61135J
|
NEG.
|
0.4-Inch (10.2mm)
|
GENERIC L.H. LOAD
with SIDE-TURN POTS
- PICKER COMPATIBLE
-
|
|
ICX853R
|
A = 3
B = 1
C = 2
|
AC & up
AB
AA
|
61154J
61135J
61135D
|
NEG.
|
0.4-Inch (10.2mm)
|
GENERIC R.H. LOAD
with SIDE-TURN POTS
- PICKER COMPATIBLE
-
|
|
ICX854
|
A = 2
B = 1
C = 3
|
AC & up
AB
AA
Other Docs
|
61170S
61170S
61170C
705207
|
NEG.
|
0.12-Inch
(3.3mm)
|
KONICA REGIUS
350 CR SYSTEM
- PICKER COMPATIBLE
-
|
|
ICX855
|
A = 2
B = 1
C = 3
|
AC & up
AB
AA
|
61154C
61135J
61135D
|
NEG.
|
0.4-Inch (10.2mm)
|
PAUSCH KS80
- PICKER COMPATIBLE
-
|
|
ICX859
|
A = 2
B = 1
C = 3
|
AD & up
AA-AC
|
61154C
61135C
|
NEG.
|
0.4-Inch (10.2mm)
|
L-F 8000 & L-F 9000 ACL
L-F TABLE BUCKY
(GRID MOTOR AT FOOT-END)
- PICKER COMPATIBLE
-
|
|
ICX862
|
A = 2
B = 1
C = 3
|
AH & up
AF-AG
AD-AE
AC
AA-AB
|
61154C
61135C
61137A
61116C
60917F
|
NEG.
|
0.4-Inch (10.2mm)
|
GENERIC L.H. LOAD
L-F 9000 R.H. LOAD
- PICKER COMPATIBLE
-
|
|
ICX874
|
A = 2
B = 1
C = 3
|
AC & up
AA-AB
|
61154C
61135A
|
NEG.
|
0.4-Inch (10.2mm)
|
L-F HUT III
OEC UROVIEW 2600
- PICKER COMPATIBLE
-
|
|
ICX877
|
A = 2
B = 1
C = 3
|
AB & up
AA
|
61154C
61135C
|
NEG.
|
0.4-Inch (10.2mm)
|
PICKER ELITE 1500 & 5000
L.H. LOAD
- PICKER COMPATIBLE
-
|
|
ICX890
|
A = 2
B = 1
C = 3
|
AF & up
AE
AA-AD
|
61150A
61150A
60917F
|
NEG.
|
0.4-Inch (10.2mm)
|
PAUSCH KS-80
- PICKER COMPATIBLE
-
|
|
ICX892
|
A = 2
B = 1
C = 3
|
AC & up
AB
AA
|
61154C
61135C
61116A
|
NEG.
|
0.4-Inch (10.2mm)
|
L-F 9000 R.H. LOAD
- PICKER COMPATIBLE
-
|
|
ICX919
|
A = 2
B = 1
C = 3
|
AC & up
AA-AB
|
61154C
60917F
|
POS.
|
0.4-Inch (10.2mm)
|
PICKER AEC, H.L. LYONS R.H. LOAD CHEST STAND - PICKER COMPATIBLE
-
|
|
ICX923
|
A = 2
B = 1
C = 3
|
AB & up
AA
|
61154C
60917F
|
NEG.
|
0.4-Inch (10.2mm)
|
PAUSCH KS-80
- PICKER COMPATIBLE
-
|
|
ICX925
|
A = 1
B = 2
C = 3
|
AA
|
60917F
|
NEG.
|
0.4-Inch (10.2mm)
|
EXIT-TYPE
REPLACES PICKER PMT
IN A CHEST FILM CHANGER
USING KEITHLEY AEC.
|
|
ICX927
|
|
|
|
|
|
PAUSCH KS-80
SEE ICX890
- PICKER COMPATIBLE
-
|
|
ICX930
|
SPOT
3.0-Inch (76mm) SQ.
|
AA & up
|
60940F
|
NEG.
|
0.4-Inch (10.2mm)
|
PICKER 1717
SPOT FILM DEVICE
- PICKER COMPATIBLE
-
|
|
ICX2822
|
A = 2
B = 1
C = 3
|
AA & up
Other Docs
|
61170S
705207
|
POS.
|
0.13-Inch (3.3mm)
|
CANON / IDC DIGITAL
RADIOGRAPHIC SYSTEM
with REMOVABLE REMOTE PRE-AMP
- PICKER COMPATIBLE
-
|